LED Floodlights Zone 2 & 22 Series PRO-N

LED floodlights for Zone 2 & 22 Series PRO-N:

PRO-N Series floodlights with LED technology combine a lightweight and compact design with high performance in terms of reliability and efficiency. The rugged housing with cooling fins provides optimal cooling for long life of the internal LED boards in an industrial environment, while an optional optical system with lenses allows the light flux to be controlled and illuminated only where needed.

The lighting fixtures can be installed in Zone 2 & 22.

Benefits and features:

  • Ex protection: II3GD Ex nR IIC T5 Gb, Ex tc IIIC T95°C Dc IP66
  • Ambient temperature: -20°C ÷ +40°C (Optional +60°C with lower temperature class)
  • Certificate: CEC 15 ATEX 045
  • Housing: Aluminum with gray epoxy coating
  • Diffuser: Impact resistant glass (4 Joule impact)
  • Swivel bracket and screws: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Swivel inputs: 1 or 3 inputs M20x1.5, depending on type
  • Power: 25W ÷ 240W
  • Luminous flux: 3,000lm ÷ 34,000lm
  • Correlated color temperature (CCT): 4,000K ÷ 5,700K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% or 24Vdc ±10% as standard
  • LED driver: On board LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
PRO48N10024DCL
Article: PRO48N10024DCL
Lighting without emergency function
LED 5.500K
100W
10000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N10024DCL25
Article: PRO48N10024DCL25
Lighting without emergency function
LED 5.500K
100W
10000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N10024DCL65
Article: PRO48N10024DCL65
Lighting without emergency function
LED 5.500K
100W
10000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N120230ACL
Article: PRO48N120230ACL
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N120230ACL25
Article: PRO48N120230ACL25
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N120230ACL65
Article: PRO48N120230ACL65
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N12024DCL
Article: PRO48N12024DCL
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N12024DCL25
Article: PRO48N12024DCL25
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N12024DCL65
Article: PRO48N12024DCL65
Lighting without emergency function
LED 5.500K
120W
12000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N125230AC
Article: PRO48N125230AC
Lighting without emergency function
LED 5.500K
125W
13750 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N150230AC
Article: PRO48N150230AC
Lighting without emergency function
LED 5.500K
150W
16500 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N150230ACM
Article: PRO48N150230ACM
Lighting without emergency function
5.500K
150W
21000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N150230ACM40
Article: PRO48N150230ACM40
Lighting without emergency function
5.500K
150W
21000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N150230ACM60
Article: PRO48N150230ACM60
Lighting without emergency function
5.500K
150W
21000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N150230ACM90
Article: PRO48N150230ACM90
Lighting without emergency function
5.500K
150W
21000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N180230ACL
Article: PRO48N180230ACL
Lighting without emergency function
LED 5.500K
180W
18000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N180230ACL25
Article: PRO48N180230ACL25
Lighting without emergency function
LED 5.500K
180W
18000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N180230ACL65
Article: PRO48N180230ACL65
Lighting without emergency function
LED 5.500K
180W
18000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N18024DCL
Article: PRO48N18024DCL
Lighting without emergency function
LED 5.500K
180W
18000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO48N18024DCL25
Article: PRO48N18024DCL25
Lighting without emergency function
LED 5.500K
180W
18000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter