LED lighting fittings in GRP for Zone 2 & 22 Series AVNL

LED Tube light fixtures in GRP for Zone 2 & 22 Series AVNL:

AVL Series LED tube light fixtures consist of a robust GRP housing with 2.5mm thick and impact resistant UV resistant polycarbonate cover. Internally, the fixtures can be equipped with standard T8 LED tubes. Up to 3 tube lamps can be installed per fixture, in lengths of 600mm and 1,200mm. Optionally, the fixtures are available with battery for emergency situations.

The lighting fixtures can be installed in zone 2 & 22.

Features:

  • Ex protection: II3GD Ex nA IIC T6 Gc, Ex tc IIIC T80°C Dc IP66
  • Ambient temperature: -25°C ÷ +40°C/+60°C  
  • Certificate: CEC 12 ATEX 050
  • Housing: Glass fiber reinforced polyester, Black
  • Diffuser: Impact resistant UV resistant polycarbonate 
  • Screws & accessories: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Gland entries: 1 or 2 entries M25
  • LED Tubes normal operation: T8 LED 600mm (Max 16W) & 1,200mm (Max 32W)
  • LED Tubes emergency: Type Cosime LTT Ex mb (CEC 14 ATEX 054 U)
  • Supply voltage: 230Vac 50/60Hz ±10% as standard
  • Battery: Ni-Cad, 3.6V

Downloads

Product
Normal operation
Emergency operation
Classifictation
LTC30Q-24DC
Article: LTC30Q-24DC
Lighting without emergency function
5.500K
26W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC30YQ-24DC
Article: LTC30YQ-24DC
Lighting without emergency function
5.500K
26W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC35Q-230AC
Article: LTC35Q-230AC
Lighting without emergency function
5.500K
35W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC35Q-24DC
Article: LTC35Q-24DC
Lighting without emergency function
5.500K
35W
4000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC35YQ-24DC
Article: LTC35YQ-24DC
Lighting without emergency function
5.500K
35W
4000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX230ACL
Article: PRO12EX230ACL
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX230ACL25
Article: PRO12EX230ACL25
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX230ACL65
Article: PRO12EX230ACL65
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX24DCL
Article: PRO12EX24DCL
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX24DCL25
Article: PRO12EX24DCL25
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12EX24DCL65
Article: PRO12EX24DCL65
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO12N230ACL
Article: PRO12N230ACL
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO12N230ACL25
Article: PRO12N230ACL25
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO12N230ACL65
Article: PRO12N230ACL65
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO12N24DCL
Article: PRO12N24DCL
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO12N24DCL25
Article: PRO12N24DCL25
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO12N24DCL65
Article: PRO12N24DCL65
Lighting without emergency function
LED 5.500K
25W
3000 lm

-
Atex Zone 2 & 22
II3G Ex nR IIC T5 Gc
II3D Ex tc IIIC T95°C IP66 Dc
PRO144EX230AC
Article: PRO144EX230AC
Lighting without emergency function
5.500K
240W
34000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO144EX230AC25
Article: PRO144EX230AC25
Lighting without emergency function
5.500K
240W
34000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
PRO144EX230AC50
Article: PRO144EX230AC50
Lighting without emergency function
5.500K
240W
34000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-