Prewired low voltage LED tubes Zone 1 & 21 Series LTC

Pre-wired Low Voltage Compact LED Tube Lights Series LTC: 

The LTC is a compact tube LED solution with pre-wired polyurethane cable. It delivers a bundled bright luminous flux and can be used for many applications. Given the compact design and rather limited power, these fixtures find application mainly in smaller areas to be illuminated such as containers, skids, machinery, gas meter rooms and others.

These lighting fixtures are already widely used on fuel and ADR tankers. The LED and electronics are extremely resistant to the voltage spikes and mains pollution caused by truck generators. The lighting fixtures can be supplied with ADR approved cable for these applications.

The lighting fittings can be installed in Zone 1, 21, 2 & 22.

Benefits and features:

  • Compact design with directional light
  • Lifespan of approximately 50,000 hours
  • Consists of polyamide end pieces and a polycarbonate diffuser
  • Is widely used in mechanical engineering and ADR Transportation
  • Available with ADR approved cable and for years already frequently installed on fuel tankers
  • Light source: Integrated LED cluster 115lm/W 5,500K 120° CRI80
  • Power consumption: 5 ÷ 35 Watt
  • Supply voltage: 24Vdc ±10%
  • Ex protection: II2GD Ex e mb IIC T5 Gb, Ex mb IIIC T95°C IP66 Db
  • Ambient temperature: -20°C ÷ +40°C/+60°C
  • Certificate: CEC 11 ATEX 120

Downloads

Product
Normal operation
Emergency operation
Classifictation
AVNL336
Article: AVNL336
Lighting without emergency function
2.800K ÷ 6.500K
Max 3x32W
7500 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNL36
Article: AVNL36
Lighting without emergency function
2.800K ÷ 6.500K
Max 1x32W
2500 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE18(1H)
Article: AVNLE18(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x16W
1250 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE18(3H)
Article: AVNLE18(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x16W
1250 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE218(1H)
Article: AVNLE218(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x16W
2500 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE218(3H)
Article: AVNLE218(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x16W
2500 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE236(1H)
Article: AVNLE236(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x32W
5000 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE236(3H)
Article: AVNLE236(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 2x32W
5000 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE36(1H)
Article: AVNLE36(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x32W
2500 lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLE36(3H)
Article: AVNLE36(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
2.800K ÷ 6.500K
Max 1x32W
2500 lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLEE18(1H)
Article: AVNLEE18(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
2.800K ÷ 6.500K

lm
13W (1hr)
1300 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNLEE18(3H)
Article: AVNLEE18(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
2.800K ÷ 6.500K

lm
4W (3Hrs)
550 lm
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
BTL15RUN240
Article: BTL15RUN240
Lighting without emergency function
5.500K
1x17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL215RUN240
Article: BTL215RUN240
Lighting without emergency function
5.500K
2x17W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL230RUN240
Article: BTL230RUN240
Lighting without emergency function
5.500K
2x35W
7200 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTL30RUN240
Article: BTL30RUN240
Lighting without emergency function
5.500K
1x35W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE15RUN240(1H)
Article: BTLE15RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE15RUN240(3H)
Article: BTLE15RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE215RUN240(1H)
Article: BTLE215RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE215RUN240(3H)
Article: BTLE215RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-