Pre-wired compact LED Tubes on AC Voltage Zone 1 & 21 Series LTC

Pre-wired compact LED Tube Lights on AC Voltage Series LTC: 

The LTC is a compact tubular LED solution with pre-wired polyurethane cable. It delivers a bundled bright luminous flux and can be used for many applications. Given the compact design and rather limited power, these luminaires mainly find application in smaller areas to be illuminated such as containers, skids, machinery, gas meter rooms and others.  

The lighting fittings can be installed in Zone 1, 21, 2 & 22.

Advantages and features:

  • Compact design with directional light
  • Glare-resistant polycarbonate tube
  • Lifespan of approximately 50,000 hours
  • Consists of polyamide end pieces and a polycarbonate diffuser
  • Frequently used in mechanical engineering
  • Light source: integrated LED cluster 90lm/W 5,500K 120° CRI80
  • Power consumption: 5 ÷ 35 Watt
  • Supply voltage: 230Vac 50/60Hz ±10%
  • Ex protection: II2GD Ex e mb IIC T5 Gb, Ex mb IIIC T95°C IP66 Db
  • Ambient temperature: -20°C ÷ +40°C/+60°C
  • Certificate: CEC 11 ATEX 120

Downloads

Product
Normal operation
Emergency operation
Classifictation
BTLE230RUN240(1H)
Article: BTLE230RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE230RUN240(3H)
Article: BTLE230RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(1H)
Article: BTLE30RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(3H)
Article: BTLE30RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(1H)
Article: BTLEE15RUN240(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(3H)
Article: BTLEE15RUN240(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
LTC05Q-230AC
Article: LTC05Q-230AC
Lighting without emergency function
5.500K
5W
450 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05Q-24DC
Article: LTC05Q-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05YQ-24DC
Article: LTC05YQ-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10A-24DC
Article: LTC10A-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-230AC
Article: LTC10Q-230AC
Lighting without emergency function
5.500K
9W
900 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-24DC
Article: LTC10Q-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10YQ-24DC
Article: LTC10YQ-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15A-24DC
Article: LTC15A-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15Q-24DC
Article: LTC15Q-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15YQ-24DC
Article: LTC15YQ-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-230AC
Article: LTC20Q-230AC
Lighting without emergency function
5.500K
17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-24DC
Article: LTC20Q-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20YQ-24DC
Article: LTC20YQ-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC30Q-230AC
Article: LTC30Q-230AC
Lighting without emergency function
5.500K
26W
2700 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter